{"id":302351,"date":"2018-12-20T12:17:27","date_gmt":"2018-12-20T11:17:27","guid":{"rendered":"https:\/\/www.deltamicroscopies.com\/produit\/model-700-1d-unmounted\/"},"modified":"2018-12-20T12:17:27","modified_gmt":"2018-12-20T11:17:27","slug":"model-700-1d-unmounted","status":"publish","type":"product","link":"https:\/\/www.deltamicroscopies.com\/en\/products\/model-700-1d-unmounted\/","title":{"rendered":"Model 700-1D,  Unmounted"},"content":{"rendered":"<h1><span style=\"font-size: 14pt;\">SPM Calibration Specimens<\/span><\/h1>\n<h2><span style=\"font-size: 12pt;\">Overall Benefits:<\/span><\/h2>\n<p>&#8211; Easier testing of your SPM. &#8211; Improved accuracy of critical dimension measurements. &#8211; Accuracy: 0.5% (1 std. dev.).<\/p>\n<h2><span style=\"font-size: 12pt;\">Features and Benefits:<\/span><\/h2>\n<p>&#8211; Holographic fabrication &#8211; assures high accuracy and precision. &#8211; Pattern height &gt; 100nm &#8211; provide excellent image contrast. &#8211; Uniform coverage of entire chip &#8211; save time (can image anywhere).<\/p>\n<h2><span style=\"font-size: 12pt;\">Description:<img decoding=\"async\" class=\"imageright alignright\" style=\"margin: 7px 0px 7px 14px; outline: #72777c solid 1px; height: 384px; text-align: left; color: #666666; text-transform: none; text-indent: 0px; letter-spacing: normal; font-size: 14px; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; max-width: 786px; orphans: 2; float: right; -webkit-text-stroke-width: 0px; background-color: transparent;\" src=\"https:\/\/www.emsdiasum.com\/microscopy\/products\/images\/80000\/80122.gif\" alt=\"SPM Calibration Specimens\" width=\"101\" height=\"384\" \/><\/span><\/h2>\n<p>&#8211; Nominal calibrated dimensions: 300 or 700 nm. &#8211; Calibration certificate: supplied with each sample, stating the dimension to the nearest 1 nm. &#8211; Pattern types: 1- or 2\u2014Dimensional. The calibrated dimension is the same for both axes for the 2-D standard. &#8211; Feature geometry: &#8211; parallel ridges (1-D, 300 or 700nm) &#8211; cylindrical posts (2-D 300nm)<br style=\"margin: 0px; padding: 0px; text-align: left; color: #666666; text-transform: none; line-height: 23.8px; text-indent: 0px; letter-spacing: normal; overflow: visible; font-size: 14px; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; word-wrap: break-word; min-height: 0px; max-width: none; orphans: 2; -webkit-text-stroke-width: 0px; background-color: transparent;\" \/>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &#8211; diamond-shaped posts (2-D 700nm) &#8211; Physical Size: 3 mm x 4 mm x 0.5mm. &#8211; Substrate: Silicon wafer. &#8211; Top surface: Tungsten film. \u00a0 The 1-D standards can be scanned using any AFM mode, including contact mode. The 2-D standards can be scanned using modes such as Tapping Mode&#x2122;, intermittent contact, and non-contact.<\/p>\n<h2><strong><span style=\"font-size: 12pt;\">Model 150-1D<\/span><\/strong><\/h2>\n<p>Accurate measurements of sub 0.5 micron features are increasingly important as nanotechnology develops an<img decoding=\"async\" class=\"imageright alignright\" style=\"margin: 7px 0px 7px 14px; outline: #72777c solid 1px; height: 131px; text-align: left; color: #666666; text-transform: none; text-indent: 0px; letter-spacing: normal; font-size: 14px; font-style: normal; font-variant: normal; font-weight: 500; text-decoration: none; word-spacing: 0px; white-space: normal; max-width: 786px; orphans: 2; float: right; -webkit-text-stroke-width: 0px; background-color: transparent;\" src=\"https:\/\/www.emsdiasum.com\/microscopy\/products\/images\/tweezers\/150-1D.jpg\" alt=\"AFM calibration specimen\" width=\"131\" height=\"160\" \/>d as conventional microfabricated structures (semiconductors, magnetic data storage devices, optical data discs) shrinking. The model 150-1D with a nominal period (pitch) of 150nm, one dimensional, fabricated on a transparent substrate (Aluminum lines on glass) is the new tool to support this work.<\/p>\n<h2><span style=\"font-size: 12pt;\"><strong>Model 750-HD<\/strong><img decoding=\"async\" class=\"imageright alignright\" style=\"margin: 7px 0px 7px 14px; outline: #72777c solid 1px; height: 147px; text-align: left; color: #666666; text-transform: none; text-indent: 0px; letter-spacing: normal; font-size: 14px; font-style: normal; font-variant: normal; font-weight: 500; text-decoration: none; word-spacing: 0px; white-space: normal; max-width: 786px; orphans: 2; float: right; -webkit-text-stroke-width: 0px; background-color: transparent;\" src=\"https:\/\/www.emsdiasum.com\/microscopy\/products\/images\/80000\/750-HD.jpg\" alt=\"scanning probe microscope calibration specimens\" width=\"131\" height=\"153\" \/><\/span><\/h2>\n<p>High Durability Calibration Reference Specimen for AFM and STM Each specimen is supplied with a calibration certificate. Can be used for AFM, STM and SEM. Has been used successfully in a hot water AFM.<\/p>\n<table style=\"height: 71px; width: 470px; border-style: solid; border-color: #000000;\">\n<tbody>\n<tr style=\"height: 28px;\">\n<td style=\"border-style: solid; border-color: #000000; width: 208.46px; height: 28px;\">Nominal pattern dimensions<\/td>\n<td style=\"border-style: solid; border-color: #000000; width: 245.54px; height: 28px;\">Pitch 750 nm<\/td>\n<\/tr>\n<tr style=\"height: 10px;\">\n<td style=\"border-style: solid; border-color: #000000; width: 208.46px; height: 10px;\">\u00a0<\/td>\n<td style=\"border-style: solid; border-color: #000000; width: 245.54px; height: 10px;\">Height 100 nm<\/td>\n<\/tr>\n<tr style=\"height: 10px;\">\n<td style=\"border-style: solid; border-color: #000000; width: 208.46px; height: 10px;\">Nominal specimen dimensions<\/td>\n<td style=\"border-style: solid; border-color: #000000; width: 245.54px; height: 10px;\">6.35 nm diameter, 0.3 mm thick<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"border-style: solid; border-color: #000000; width: 208.46px; height: 23px;\">Composition<\/td>\n<td style=\"border-style: solid; border-color: #000000; width: 245.54px; height: 23px;\">Solid Nickel<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2><strong><span style=\"font-size: 12pt;\">Model PT<\/span><\/strong><\/h2>\n<p>Phase Imaging Test Specimen (verify TappingMode&#x2122; phase contrast and resolution). Phase Imaging is a sharp probe, which is brought into proximity with the specimen surface. The probe is oscillated vertically near its mechanical resonance fre-quency. As the probe lightly taps the surface, the amplitude of oscillation is reduced and the AFM uses this change in amplitude in order to track the surface topography. In addition <img decoding=\"async\" class=\"imageright alignright\" style=\"margin: 7px 0px 7px 14px; outline: #72777c solid 1px; height: 160px; text-align: left; color: #666666; text-transform: none; text-indent: 0px; letter-spacing: normal; font-size: 14px; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; max-width: 786px; orphans: 2; float: right; -webkit-text-stroke-width: 0px; background-color: transparent;\" src=\"https:\/\/www.emsdiasum.com\/microscopy\/products\/images\/abc\/PT.jpg\" alt=\"Atomic force microscope calibration specimens\" width=\"160\" height=\"160\" \/>to its amplitude, the probe motion can be characterized by its phase relative to a driving oscillator. The phase signal changes when the probe encounters regions of different composition. Phase shifts are registered as bright and dark regions in phase images, comparable to the way height changes are indicated in height images. Phase images often show extraordinary contrast for many composite surfaces of technological and scientific interest. These include contamination deposits, discontinuous (i.e. defective) thin films, devices built of composite materials (e.g. magnetic recording heads), and cross-sectional specimens of composite materials. Both inorganic and organic materials can be examined. We have found that phase imaging is more convenient and gentler than other methods, which are based on contact mode operation. It routinely achieves lateral resolution of 10 nm.<\/p>\n<h2><strong><span style=\"font-size: 12pt;\">Models 300-2D, 300-1D, 700-2D and 700-1D<\/span><\/strong><\/h2>\n<p>All mounted on 15 mm steel disk.<\/p>\n<h2><strong><span style=\"font-size: 12pt;\">Models 300-1D and 300-2D<\/span><\/strong><\/h2>\n<p><img decoding=\"async\" class=\"alignnone\" style=\"outline: #72777c solid 1px; height: 132px; text-align: left; color: #666666; text-transform: none; text-indent: 0px; letter-spacing: normal; font-size: 14px; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; max-width: 786px; orphans: 2; -webkit-text-stroke-width: 0px; background-color: transparent;\" src=\"https:\/\/www.emsdiasum.com\/microscopy\/products\/images\/80000\/300-1D.jpg\" alt=\"AFM calibration specimens\" width=\"132\" height=\"132\" \/> Parallel Ridges Pitch 288 W-coated Photoresist on Si use contact or TappingMode<\/p>\n<h2><strong><span style=\"font-size: 12pt;\">Models\u00a0 300-2D<\/span><\/strong><\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/www.emsdiasum.com\/microscopy\/products\/images\/80000\/300-2D.jpg\" alt=\"Scanning force calibration specimens\" width=\"136\" height=\"141\" \/> Array of Posts Pitch 297 Al bumps on Si use contact or TappingMode<\/p>\n<h2><strong><span style=\"font-size: 12pt;\">Models 700-1D\u00a0<\/span><\/strong><\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/www.emsdiasum.com\/microscopy\/products\/images\/80000\/700-1D.jpg\" alt=\"Microscope SPM calibration specimen\" width=\"142\" height=\"141\" \/> 700-1D Parallel Ridges Pitch 700 W-coated Photoresist on Si use contact or TappingMode<\/p>\n<h2><strong><span style=\"font-size: 12pt;\">Models\u00a0 700-2D<\/span><\/strong><\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/www.emsdiasum.com\/microscopy\/products\/images\/80000\/700-2D.jpg\" alt=\"Microscope SPM calibration specimen\" width=\"140\" height=\"140\" \/> 700-2D Array of Posts Pitch 700 W-coated Photoresist on Si use TappingMode <strong>References<\/strong> 1. Pereira, D.E.D. &amp; Claudio-da-Silva, Jr., E. \u201cImprovement of AFM as an analytical Instrument for Residual Lignin Characterization\u201d in: Proceedings International Symposium on Wood and Pulping Chemistry, Helsinki, Finland, June 1995. 2. Pereria, D.E.D, Chernoff, D., Claudio-da-Silva, Jr. E., &amp; Cemuner, B.J., \u201cThe use of AFM to investigate the delignification process: Part I \u2013AFM performance by differentiating pulping processes\u201d, to be published.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>SPM Calibration Specimens Overall Benefits: &#8211; Easier testing of your SPM. &#8211; Improved accuracy of critical dimension measurements. &#8211; Accuracy: 0.5% (1 std. dev.). Features and Benefits: &#8211; Holographic fabrication &#8211; assures high accuracy and precision. &#8211; Pattern height &gt; 100nm &#8211; provide excellent image contrast. &#8211; Uniform coverage of entire chip &#8211; save time [&hellip;]<\/p>\n","protected":false},"featured_media":288086,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"off","_et_pb_old_content":"","_et_gb_content_width":"","inline_featured_image":false},"product_brand":[],"product_cat":[1412,1096],"product_tag":[],"class_list":{"0":"post-302351","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-spm-calibrator-en","7":"product_cat-standards","9":"first","10":"instock","11":"taxable","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Model 700-1D, Unmounted - Delta Microscopies<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.deltamicroscopies.com\/en\/products\/model-700-1d-unmounted\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Model 700-1D, Unmounted - Delta Microscopies\" \/>\n<meta property=\"og:description\" content=\"SPM Calibration Specimens Overall Benefits: &#8211; Easier testing of your SPM. &#8211; Improved accuracy of critical dimension measurements. &#8211; Accuracy: 0.5% (1 std. dev.). Features and Benefits: &#8211; Holographic fabrication &#8211; assures high accuracy and precision. &#8211; Pattern height &gt; 100nm &#8211; provide excellent image contrast. &#8211; Uniform coverage of entire chip &#8211; save time [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.deltamicroscopies.com\/en\/products\/model-700-1d-unmounted\/\" \/>\n<meta property=\"og:site_name\" content=\"Delta Microscopies\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.deltamicroscopies.com\/wp-content\/uploads\/2018\/12\/700-1D.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"160\" \/>\n\t<meta property=\"og:image:height\" content=\"159\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Model 700-1D, Unmounted - Delta Microscopies","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.deltamicroscopies.com\/en\/products\/model-700-1d-unmounted\/","og_locale":"en_US","og_type":"article","og_title":"Model 700-1D, Unmounted - Delta Microscopies","og_description":"SPM Calibration Specimens Overall Benefits: &#8211; Easier testing of your SPM. &#8211; Improved accuracy of critical dimension measurements. &#8211; Accuracy: 0.5% (1 std. dev.). Features and Benefits: &#8211; Holographic fabrication &#8211; assures high accuracy and precision. &#8211; Pattern height &gt; 100nm &#8211; provide excellent image contrast. &#8211; Uniform coverage of entire chip &#8211; save time [&hellip;]","og_url":"https:\/\/www.deltamicroscopies.com\/en\/products\/model-700-1d-unmounted\/","og_site_name":"Delta Microscopies","og_image":[{"width":160,"height":159,"url":"https:\/\/www.deltamicroscopies.com\/wp-content\/uploads\/2018\/12\/700-1D.jpg","type":"image\/jpeg"}],"twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.deltamicroscopies.com\/en\/products\/model-700-1d-unmounted\/","url":"https:\/\/www.deltamicroscopies.com\/en\/products\/model-700-1d-unmounted\/","name":"Model 700-1D, Unmounted - Delta Microscopies","isPartOf":{"@id":"https:\/\/www.deltamicroscopies.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.deltamicroscopies.com\/en\/products\/model-700-1d-unmounted\/#primaryimage"},"image":{"@id":"https:\/\/www.deltamicroscopies.com\/en\/products\/model-700-1d-unmounted\/#primaryimage"},"thumbnailUrl":"https:\/\/efb7cwj5g4q.exactdn.com\/wp-content\/uploads\/2018\/12\/700-1D.jpg?strip=all","datePublished":"2018-12-20T11:17:27+00:00","breadcrumb":{"@id":"https:\/\/www.deltamicroscopies.com\/en\/products\/model-700-1d-unmounted\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.deltamicroscopies.com\/en\/products\/model-700-1d-unmounted\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.deltamicroscopies.com\/en\/products\/model-700-1d-unmounted\/#primaryimage","url":"https:\/\/efb7cwj5g4q.exactdn.com\/wp-content\/uploads\/2018\/12\/700-1D.jpg?strip=all","contentUrl":"https:\/\/efb7cwj5g4q.exactdn.com\/wp-content\/uploads\/2018\/12\/700-1D.jpg?strip=all","width":160,"height":159,"caption":"Model 700-1D, Unmounted"},{"@type":"BreadcrumbList","@id":"https:\/\/www.deltamicroscopies.com\/en\/products\/model-700-1d-unmounted\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.deltamicroscopies.com\/en\/home-3\/"},{"@type":"ListItem","position":2,"name":"Our products","item":"https:\/\/www.deltamicroscopies.com\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"Model 700-1D, Unmounted"}]},{"@type":"WebSite","@id":"https:\/\/www.deltamicroscopies.com\/en\/#website","url":"https:\/\/www.deltamicroscopies.com\/en\/","name":"Delta Microscopies","description":"Des microscopistes \u00e0 votre service.","publisher":{"@id":"https:\/\/www.deltamicroscopies.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.deltamicroscopies.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.deltamicroscopies.com\/en\/#organization","name":"Delta Microscopies","url":"https:\/\/www.deltamicroscopies.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.deltamicroscopies.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/efb7cwj5g4q.exactdn.com\/wp-content\/uploads\/2019\/09\/DELTAM_LOGO_RVB-1-1.png?strip=all&lossy=1&ssl=1","contentUrl":"https:\/\/efb7cwj5g4q.exactdn.com\/wp-content\/uploads\/2019\/09\/DELTAM_LOGO_RVB-1-1.png?strip=all&lossy=1&ssl=1","width":688,"height":177,"caption":"Delta Microscopies"},"image":{"@id":"https:\/\/www.deltamicroscopies.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.instagram.com\/emsdiasum\/","https:\/\/www.youtube.com\/channel\/UCkSsQQq74DhyLXNg_9RPorQ"]}]}},"_links":{"self":[{"href":"https:\/\/www.deltamicroscopies.com\/en\/wp-json\/wp\/v2\/product\/302351","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.deltamicroscopies.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.deltamicroscopies.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.deltamicroscopies.com\/en\/wp-json\/wp\/v2\/comments?post=302351"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.deltamicroscopies.com\/en\/wp-json\/wp\/v2\/media\/288086"}],"wp:attachment":[{"href":"https:\/\/www.deltamicroscopies.com\/en\/wp-json\/wp\/v2\/media?parent=302351"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.deltamicroscopies.com\/en\/wp-json\/wp\/v2\/product_brand?post=302351"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.deltamicroscopies.com\/en\/wp-json\/wp\/v2\/product_cat?post=302351"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.deltamicroscopies.com\/en\/wp-json\/wp\/v2\/product_tag?post=302351"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}